EnsadRear flip hydraulic plate flipperQuality level
release time:2024-04-18 03:41:05

The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices,EnsadAluminum alloy lifting platform, the order of shipment, and the alignment of handrail turns during continuous arrangement.Ensad,The elevator stops on the first floor and the door does not move: the fire emergency landing function of the elevator is triggered by smoke or thermal sensors inside the building.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified,Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed,EnsadSingle and double column aluminum alloy lifting platform, and the site has not yet been constructed, is under construction, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.


EnsadRear flip hydraulic plate flipperQuality level



The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Elevator does not close the door or repeatedly opens and closes the door: there are debris blocking the light curtain or door contact plate at the entrance or sill.Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation,EnsadAluminum alloy mast type lifting platform, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof, high-temperature resistant sturdy and durable, safe and reliableinstall,The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.


EnsadRear flip hydraulic plate flipperQuality level



The front room of the fire elevator is equipped with indoor fire hydrants.Inspection environment,Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.The braking system of the elevator is usually closed, which means it is in the braking state when there is no power, and only when it needs to be turned on, will the power turn on the brakes. So as soon as there was a power outage, the brakes closed and the elevator was braked in mid air. When the elevator descends abnormally, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.Ensad,When the normal power supply is cut off, the lighting inside the non fire elevator has no power, while there is still lighting inside the fire elevator.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.


comment list
  • toda machinery co., ltd.

    After looking for the EnsadRear flip hydraulic plate flipper from your family for a long time, I mustered up the courage and the quality of the inspection was very good.

  • Sales and maintenance of machinery and equipment

    EnsadRear flip hydraulic plate flipper It’s really good, how long does it take to arrive after the departure?

  • Jingcanghong Stainless Steel Sales Company

    Can you give me a discount next time I buy it, EnsadRear flip hydraulic plate flipper The quality is good, and I will live up to the boss

  • Kangling Machinery Media Co., Ltd.

    Can you give me EnsadRear flip hydraulic plate flipper detailed specification data?

  • Li Ping

    It's rare to buy EnsadRear flip hydraulic plate flipper, I saw such a good store. The price is very favorable, the service is also very good, and the things are good. Give me a good encouragement this

©2009-2024Metal Microblog  Sitemap