JiusamoMedical freezingHow to install and operate reasonably
release time:2023-05-12 05:36:43

Frequently observe the operation state of the heart compressor of the cold storage equipment and its exhaust temperature. During the season change operation, pay special attention to the operation state of the system and adjust the liquid supply and condensation temperature of the system in time.During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.Jiusamo,For the selection and preparation of the ground location of the cold storage, the design of the cold storage shall consider the necessary auxiliary engineering buildings and equipment, such as working intermediates, packaging and combing room, special tool warehouse, loading and unloading platform, etc.Cold storage has strong stability. Polyurethane foam technology makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is under the unfavorable local temperature and humidity conditions,The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration the characteristics of the cold storage still do not separate and fall off from the carrier layer and remain stable under normal conditions.Jericho, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.Application of parallel compressor in cold storage: the requirement of refrigeration capacity is large, and to refrigeration compressors under Malige need to be used on weekdays; Long term operation, large load peak valley difference and significant departmental load; Frozen and refrigerated objects are novel foods that are easy to decay and degenerate, and have strict requirements for temperature and humidity.The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.


JiusamoMedical freezingHow to install and operate reasonably



Danfoss thermal valve is adopted for the thermal valve of the cold storage, with guaranteed quality; Due to the high temperature requirements of the cold storage and the high degree of automation and regulation of the temperature, the temperature system of the cold storage adopts microcomputer full-automatic, does not need special people to operate, and can be remotely controlled. When the temperature exceeds the specified range, it will automatically alarm, which is of great significance to the proper preservation of the cold storage.During the welding of refrigeration pipeline, a blowdown outlet shall be reserved to blow the sewage from high and low pressure with nitrogen in sections. After the sectional blowing is completed, the whole system shall be blown until no dirt is found. The blowdown pressure is .MPa.Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.Create brilliance,The quick freezing storehouse of vegetables and fruits is not suitable to use exhaust cooling, but use fan to supply air for refrigeration, because the gas in the quick freezing storehouse needs to be circulated and dispersed regularly to avoid carbon oxide poisoning caused by high concentration of carbon oxide in local areas. Therefore, in the quick freezing warehouse the refrigeration equipment needs to be used together with the air conditioning equipment. The selection of refrigeration equipment is different from that of low-temperature freezer and ordinary quick freezing warehouse.Floor insulation of medium-sized cold storage the structure of medium-sized cold storage is what we often call the surface, that is, the top and wall are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, while the ground needs to be insulated separately. At present, the common operations in the market are: laying the ground with XPS extruded board, laying moisture-proof and steam isolating SPS materials above and below the extruded board respectively, and then pouring concrete or reinforced concrete.We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, and the penetration of the envelope is carried out from outside to inside all year round. R gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is, to form a vapor barrier layer.


JiusamoMedical freezingHow to install and operate reasonably



Where do you need to build the refrigerator, the size of the refrigerator or the storage capacity (size, storage capacity, ton, cubic meter, frame, box); What products are stored in the built cold storage? The actual storage temperature, storage time and setting temperature can be indicated by specific regulations; If your cold storage becomes larger, the temperature of goods in and out of the warehouse the frequency of opening and closing the door, etc. If this is clear, it is the selection of raw materials, such as refrigeration compressors,JiusamoProfessional installation of cold storage, refrigeration units, industrial cooling fans / pipe slots, thermal insulation materials, coolers, temperatures and other refrigeration equipment.property right,The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition, it shall be conducive to production, layout and wind speed field description of refrigeration equipment are suitable for the refrigeration needs of various goods. Equipped with perfect storage temperature active detection, recording and active equipment.The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.JiusamoWith the rapid development of modern commerce, the original cold storage for the purpose of product storage can no longer meet the rapid, accurate and small batch circulation needs of modern commodities. Therefore, the logistics center cold storage cold chain for the purpose of product distribution came into being and developed rapidly,JiusamoPrice of small installed cold storage, playing a more and more important role in the commodity circulation chain. What are the characteristics of the rapid development of cold storage construction?The service life of polyurethane cold storage insulation material foam is: besides the basic performance of the initial stage of polyurethane foam, the deterioration of foam performance is also a very important index. When the white material is prepared,JiusamoInstallation cold storage manufacturer, the surface of some polyester materials can make the foam have better toughness and impact resistance, but it will become brittle after use for a long time in the cold storage, and will no longer resist impact and collision. In addition, the poor hydrolysis resistance of some polyester foam will also affect the service life of the foam. It adopts polyether structure, but generally disappears after a few days, and then maintains the stable performance of cold storage insulation materials for a long time.. Maintenance of food cold storage. In a position convenient for operation outside the door of the refrigerator room, a main switch for cutting off the power supply of the refrigeration compressor shall be set. This switch shall be able to stop the operation of the refrigeration compressor, and relevant signs shall be set. If the mechanical panel is set in the main room, a button switch shall be added next to each refrigeration compressor.

comment list
©2009-2024Metal Microblog  Sitemap