There should be excellent drainage pipe standard around the warehouse, the soil temperature should be low, there should be interlayer under the cold storage, and maintain good natural ventilation. Maintaining dryness is very important for the cold storage. In addition, before the construction of the cold storage, the phase electricity of the relative volume shall be built according to the output power of the refrigeration unit. If the cold storage is water-cooled and radiating, the tap water pipeline shall be paved and the FRP cooling tower shall be built.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame,Akos ParkFood cold storage installation company, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.Akos ParkAfter startup, first listen to whether the sound of the compressor is normal, and see whether the condenser and cooling fan operate normally.Danfoss thermal valve is adopted for the thermal valve of the cold storage, with guaranteed quality; Due to the high temperature requirements of the cold storage and the high degree of automation and regulation of the temperature, the temperature system of the cold storage adopts microcomputer full-automatic does not need special people to operate, and can be remotely controlled. When the temperature exceeds the specified range, it will automatically alarm, which is of great significance to the proper preservation of the cold storage.Glenmore Park,Moreover, polyurethane does not produce harmful gas at high temperature.Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit, electric control system and other components of the cold storage. The connecting pipes shall be closely connected, the size of the refrigerator or the storage capacity (size, ton, cubic meter, frame, box); What products are stored in the built cold storage? The actual storage temperature, storage time and setting temperature can be indicated by specific regulations; If your cold storage becomes larger, you need to master your individual storage volume, the temperature of goods in and out of the warehouse, the frequency of opening and closing the door, etc. If this is clear, it is the selection of raw materials, such as refrigeration compressors, refrigeration units, industrial cooling fans / pipe slots, thermal insulation materials, coolers, doors, temperatures and other refrigeration equipment.Disadvantages: high precision requirements, shape and position tolerances are in micron level; No exhaust valve poor off design performance; The working chamber is not easy to implement external cooling, so it can only compress the gas with small adiabatic index or internal cooling; Large displacement scroll refrigeration unit is difficult to realize. The receiving teeth are high, the displacement is large, the diameter is large, and the unbalanced rotation mass increases.The use of large-scale cold storage is naturally very strict in installation and material selection. Therefore, in the face of the above possible situations, we can strictly screen the insulation board materials of cold storage, which can effectively alleviate or solve the above problems. However, at present there are many fields using cold storage insulation board, so the details of the use environment should be considered for the wood making of many such products in the market.Quality risk,Akos ParkWhich pharmaceutical cold storage has been installed,Commissioning cold storage. After all parts of the cold storage are installed and connected, the cold storage can be started for cold storage commissioning. According to the needs of customers, adjust the value of the cold storage, the cold storage can reach the predetermined temperature, the cooling speed and the operation of the cold storage are normal, and the cold storage can be delivered for use. The cold storage installation unit shall also provide the cold storage user with training on cold storage use and management knowledge, as well as some after-sales training.If there is more air or refrigerant oil in the evaporator, the heat transfer effect will be reduced: once more refrigerant oil is attached to the inner surface of the evaporator heat transfer tube, if there is more air in the heat transfer tube, the heat exchange area of the evaporator will be reduced, the heat transfer efficiency will be significantly reduced, and the decline rate of warehouse temperature will be slowed down.During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking, the distance between the goods and the goods must be cm. At the same time, the distance between the goods and the cold fan should also be cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.


Akos ParkProfessional cold storage installationWholesale preferred



The cold storage board uses light polyurethane as the inner material of the cold storage board. The advantage of polyurethane is that the thermal insulation performance is very good. The exterior of polyurethane cold storage board is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is to prevent the temperature transmission of cold storage board due to large internal and external temperature difference, so as to make the cold storage more energy-saving and improve the working efficiency of cold storage.original, light and thin walls are made of rigid polyurethane foam at the same time as structural materials making the whole structure have the advantages of light weight, large span and high load. The thinner polyurethane sandwich plate can meet the relevant provisions on building energy consumption limit, which allows the use of thinner plates during construction and saves building space.However, not all controlled atmosphere reservoirs can choose to adjust with a large depth, which still needs to be determined according to the actual needs of fans and places. We can adjust the energy-saving effect of the control fan from the production design link, coupled with the user's energy-saving effect of the hot air fan, so that the energy-saving effect of the hot air fan will be significantly improved.There are many application scenarios of cold storage, which are different. For a long time, it provides various cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, on-site settlement, and has offices all over the country for long-term cooperation. Different purposes, functions and designs, so what needs to be understood in cold storage design?Akos Park,Polyurethane with good fire resistance and flame retardancy is a kind of refractory and self extinguishing material after adding flame retardant. In case of fire, it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be sealed as a whole after systematic fire prevention treatment to form non combustible products.Now let's analyze the production and use requirements of the cold storage. There is no condensation in the cold storage. Condensation in the cold storage or in the insulation layer is harmful. During the drying process of the new wall or under winter conditions, when the water vapor with high indoor temperature migrates outdoors, it is impossible to condense in the wall due to the obstruction of the cold storage.Fault phenomenon: fan motor overload, fan deformation; Fan motor fault; Fan motor thermal relay fault (aging); Loose wiring; Cooler blocked; Large exhaust resistance. Cold storage fault phenomenon: dryer does not operate, compressor line is disconnected, fuse is blown, thermal relay acts, high voltage switch acts, compressor is locked, line is falsely connected or loose fault phenomenon: it stops in a short time after drying, ambient temperature is too high, condenser is blocked

comment list
©2009-2024Metal Microblog  Sitemap