and the oil inlet filter is blocked; The fuel supply pump has drawbacks; Check the wear and tear of the one-way valve core and valve seat
The lifting force of the scarifier is not strong or the lifting force is weak: the pressure regulation of the overflow valve does not meet the need to adjust the pressure to the required value; Refer to cleaning item above for leakage in the oil cylinder; The directional valve is stuck or leaking internally; The oil level is too low, and check if the one-way valve spring is tired or deformed.The daily maintenance of guide rail type cargo elevators should ensure that the transmission position where the grease nipple is located needs to be lubricated twice a month. For areas where grease cannot be added, it is necessary to clear the oil circuit or replace the grease nipple until butter can be added. Otherwise, it is prohibited to use the equipment.Fort Worth,When using the hydraulic lifting platform, it is also necessary to check for overheating, as this equipment is equipped with a motor. If the motor is overheated, it may cause damage to the motor. However, replacing a motor is relatively expensive. Therefore, during driving or trial operation, if the motor is found to be overheated, it should be stopped immediately, and then the fault that caused the motor to overheat should be checked and eliminated,Fort WorthHydraulic fixed lifting platform, Only then can the machine continue to be used.The daily maintenance of guide rail type lifting equipment should pay attention to regular inspection and maintenance, eliminate hidden dangers, eliminate faults, and achieve these benefits for improving work efficiency, extending equipment service life,Fort Worthhydraulic lift, and ensuring the safety performance of the elevator.Kirtipur,Regular inspection and maintenance, eliminating hidden dangers, and troubleshooting are beneficial for improving work efficiency, extending equipment service life, and ensuring the safety performance of elevators.Precautions for daily maintenance of hydraulic elevator: Check all hydraulic pipelines and joints of the hydraulic elevator. The pipelines must not be damaged, and the joints must not be loose. All joints must be tightened.Check the rollers, intermediate shafts, it affects the speed. If the goods are too light, it is necessary to quickly park the car, remove obstacles, and then continue running. The motor bearings should be smooth and excellent.Inspection items,Remove and disassemble the hydraulic lift cargo elevator lowering valve, blow out the plunger with compressed air, then install it and reinstall it.Familiarity with the usage process and without a doubt, this is the first thing to understand. There are two ways to understand it: first, carefully read the user manual provided by the manufacturer when the hydraulic lifting platform leaves the factory; The second is the equipment that needs to be installed. A professional installation technician will be dispatched to install the hydraulic lifting platform. After the installation is completed, relevant users will be trained on the operating process and safety precautions of the hydraulic lifting platform, and some maintenance matters in the future will also be explained; What should be paid attention to during the running-in period when using hydraulic lifting platforms? Check the wear of components. For newly processed and assembled components, there may be subtle deviations in shape and size that require a period of time for running-in. Therefore, during the running-in period, it is necessary to pay attention to whether there is any rapid wear. If there is any, the manufacturer of the hydraulic lifting platform should handle it in a timely manner to avoid equipment failure; Work between the pins and bearings to ensure that they are not worn, and add some engine oil or grease appropriately; Confirm if there is any noise during the running-in period. If it is found that the hydraulic lifting platform is noisy during operation, there is no need to worry in the early stage. If there are no major problems, run it several times more. After the running-in, the noise will naturally disappear. However, if there is noise for a long time and no signs of fading, please make sure to promptly produce it and solve the problem; Regularly check if the components are loose. Before use, check if there are any signs of looseness in screws, nuts, retaining rings, oil pipe joints, etc. If there are any,Fort WorthHydraulic lifting platform 18 meters, please reinforce or replace them in a timely manner to avoid accidents.Motor does not rotate: The motor is broken, and the manufacturer will handle it. We are a long-term manufacturer of scissor type elevators. Welcome to inquire
The main structure and purpose of a guide rail elevator: The mechanical part of a guide rail elevator mainly includes three parts: a lifting device, a track device, and a belt changing device. The lifting device is mainly used to suspend the person being lifted, which is the core part of the entire mechanism. The track device is mainly used to provide movement trajectory, bracket, worm gear, guide mechanism, lifting arm, upper and lower shells, etc. The gear mechanism mainly includes large and small gears, winding pulleys, central shafts, and safety devices composed of stop buckles and torsion springs.Market trend, only the power supply needs to be connected and all technical indicators meet the design requirements. When in use, and the hydraulic and electrical systems basically do not need to be adjusted.Now we have an increasing demand for cargo elevators. Let me introduce the maintenance work of guide rail cargo elevators to you. When we use a guide rail elevator in our daily life, we need to regularly inspect, maintain, and maintain it. This not only extends the service life of the guide rail elevator, but also makes it more powerful when working! For example the transmission part should have sufficient oil, and vulnerable parts must be regularly inspected, repaired, or replaced. Mechanical bolts especially parts that frequently vibrate, such as slewing bearings and lifting arm connecting bolts, should be checked for looseness. If there is looseness, it must be tightened or replaced immediately. Below is an introduction to the steps of maintenance: important maintenance work for guide rail elevators. Regularly check the tire pressure and bearing condition of the guide rail elevators to ensure they are in good condition; Regularly check whether the structure of the bracket and panel is in good condition, and add oil and grease to the bearings and components in a timely manner, once a month; Vulnerable parts must be regularly inspected, repaired, or replaced. Parts that frequently vibrate, such as bolts and slewing bearings, should be checked for looseness. If there is looseness, it must be tightened or replaced immediately.Are there any damages to the wires and cables of the department. We need to quickly bandage and replace the damaged department.Fort Worth,Loose motor fixing screws: When the motor fan rotates, there is a sound. If the screws fixing the motor are loose, coupled with the vibration of the motor itself the motor collides with other components, resulting in a sound; The joints of each pin shaft are dry, lacking oil, and there is hard friction between the iron parts, there is air in the hydraulic oil. You can open the exhaust hole, add gas, and then tighten it again; Hydraulic oil solidification: replace the hydraulic oil; Oil leakage: Check if there is any oil leakage at the interfaces of each oil pipe. If there is any oil leakage, replace it in a timely manner; Motor reversal: Check for wiring errors; (Manufacturers of hydraulic lifting platforms who do not understand electricity in a timely manner)The inconsistent rotation axis of the support rod in the middle of the hydraulic lifting platform results in the lifting platform being unable to function properly, causing serious damage to the platform and causing the table to tilt. Please carefully check that the general shear type high-altitude work platform was not strictly tested for tilt before leaving the factory, and was put into the market, causing many accidents. For small enterprises, they are not very concerned about this aspect of tilt detection, This is also why there are such a large number of lifting equipment with this problem. The problems with the oil cylinder and power unit system are often due to insufficient power and substandard oil cylinder quality, which are also very important issues for enterprises themselves.Check the hydraulic oil quality and level. When the lifting platform is raised to a high position, the hydraulic oil level should be - millimeters higher than the bottom of the oil tank. When the color of the hydraulic oil darkens the oil becomes sticky, or there are foreign objects such as gravel in the oil, the hydraulic oil should be replaced in a timely manner. The hydraulic system of the lifting platform should be checked for hydraulic and pipeline connections. If the pipeline is damaged, it should be replaced immediately; When there is looseness in the connection part, tighten the pipe joint.